12V Controller with fitted overrun timer and automatic humidistat. Humidistat automatically switches on at 70% relative humidity.
Control for the 12V Safety Extra Low Voltage fans is to be made by a mains transformer unit with SELV output. These controllers must only be fitted outside zone 2 of a bathroom. Each controller is supplied complete with a 25mm deep surface pattress box. Units can alternatively be flush wall mounted if desired.
Technical Specification:
Voltage: 230V AC – 50Hz
Neon Indicator: Yes
IP Rating: IP30
Output: 12V AC, 50Hz, 30W Max SELV
Class: Class II double insulated
Conforms to: BS EN 60335-1:2002 BS EN 60335-2-80:2003
Dimensions: H80 x W145 x D55mm